The seal sets should be used together with suitable
guide elements. The fitting areas must be cleaned and
trimmed carefully before fitting. When fitting the PTFE
Glide Seal sets, the O-ring should be placed in the
groove first. In the case of inside sealing applications
the sealing ring must then be pressed into a kidney
shape with fitting pliers and inserted in its groove.
In the case of outside sealing applications it must
be expanded with a fitting sleeve and expansion mandrel
and inserted in its groove.
A divided fitting area should be provided for rod seal
sets and corresponding wipers up to a diameter of 30
mm. The sealing element should be restored to its original
shape with a suitable calibration sleeve or calibration
mandrel. The necessary fitting and calibration tools
can be delivered on request.
|